1
1
/
/
/
/
150 Watt, Constant Voltage, LY150W, Compact

Product Categories

All categories

CONTACT US

B2, Guangming smart city, Shenzhen, China

+86 755 82285515 (Tech)
+86 755 82285575 (Sales)

+86 755 82285572

Skype 1: YG-wgm (Tech.)
Skype 2: YG.service (Sales)

QQ 1: 591454232 (Tech.)
QQ 2: 3132420015 (Sales)
QQ 3: 1302388748 (Sales)

150 Watt, Constant Voltage, LY150W, Compact

Product type: Compact and efficient, constant-voltage-driven
Application: LED Street Lights, LED Tunnel Lights, LED Grille
Size: 170mm(L)×59mm(W)×37mm(H)
Weight: 850g
Warranty: Five years
Products detail
Product parameters
Series model
Product type:
Compact and efficient, constant-voltage-driven
Application:
LED Street Lights, LED Tunnel Lights, LED Grille
Size:
170mm(L)×59mm(W)×37mm(H)
Weight:
850g
Warranty:
Five years

      LY150W Series, Compact & Efficient

1. Drive Mode: Constant Voltage

2. Technology: PFC + LLC

3. Output Power: 150W Max.

4. Input Voltage: 90 to 305VAC,47-63HZ

5. Number of Outputs: One

6. Output Voltages: 5 ~ 428Vdc

7. Output Currents: 350mA - 10000mA

8. Safety: EN61347, J61347 ( H20 ), UL8750, CSA C22.2

9. EMC: EN55015, J55015 ( H20 ), FCC 47CFR Part 15 Class B

a. Comply with PSE, CE CCC

b. RoHs compliant;

c. Metal Shell, Silicone Potting, Up to 120°C;

d. Compact, Lightweight Design;

e. Water Resistant and Dust Proof Design: IP66, NEMA4,

for Dry, Damp, Wet Locations;

f. Small electrical box for installation;

g. Active Power Factor Correction technology to reduce

power consumption;

h. Safety Isolation between Primary and Secondary.

i. Surge Immunity ( Lightning Protection ):

Comply with EN61000-4-5, AC line to line 2KV.

We could not find any corresponding parameters, please add them to the properties table

1. Operating Temperature: −30 to +60°C;

2. Storage Temperature: −40 to +85°C;

3. Humidity (non-condensing): 5% to 95%RH;

4. Cooling: Convection;

5. Vibration Frequency: 5 ~ 55HZ/2g, 30 minutes;

6. Impact Resistance: 1g/S;

7. MTBF@40°C: 500,000 hours @ Full Load per MIL-217 Notice 2.;

8. LIFE@25°C: 100,000 hours @ Full Load per MIL-217 Notice 2.;

9. Safety: CISPR 22 CLASS B, CISPR 14-1 CLASS B,

EN61000-3-2 & EN61000-3-3 Class C,

GB19510.14-2009, GB19510.1-2009,

GB17743.1-2007, GB17625.1-2003

a. Maximum Input Current: 2.00A (@ 120V, full load);

b. Input Surge Current: <50A (25°C, 230V, cold start);

c. Constant Voltage Regulation: ±3%, Over Input Line Variation;

d. Load Regulation Accuracy: ±3%;

e. Output Voltage Ripple: <1%*Io

f. Leakage Current: 400uA typical; Hold up time: half cycle;

g. Protection: Output over-voltage protection;

Output over-current protection;

Output short circuit, auto-recovery;

Lightning & transient protection built in.

Compact & Efficient

Input

Voltage

Vac

 

Power Factor

Output

Voltage

Vdc

Current

Max.

mA

Voltage

Accuracy

%

Typical

Efficiency

%

Location

LY150W Series

@120V

@230V

LY150W-428 90~305 0.99 0.95 428 350 ±5 94 Outdoor
LY150W-333 90~305 0.99 0.95 333 450 ±5 94 Outdoor
LY150W-214 90~305 0.99 0.95 214 700 ±5 94 Outdoor
LY150W-142 90~305 0.99 0.95 142 1050 ±5 93 Outdoor
LY150W-107 90~305 0.99 0.95 107 1400 ±5 93 Outdoor
LY150W-85 90~305 0.99 0.95 85 1750 ±5 93 Outdoor
LY150W-71 90~305 0.99 0.95 71 2100 ±5 92 Outdoor
LY150W-61 90~305 0.99 0.95 61 2450 ±5 92 Outdoor
LY150W-53 90~305 0.99 0.95 53 2800 ±5 92 Outdoor
LY150W-47 90~305 0.99 0.95 47 3150 ±5 92 Outdoor
LY150W-42 90~305 0.99 0.95 42 3500 ±5 91 Outdoor
LY150W-35 90~305 0.99 0.95 35 4200 ±5 90 Outdoor
LY150W-30 90~305 0.99 0.95 30 5000 ±5 90 Outdoor
LY150W-24 90~305 0.99 0.95 24 6250 ±5 89 Outdoor
LY150W-18 90~305 0.99 0.95 18 8330 ±5 88 Outdoor
LY150W-15 90~305 0.99 0.95 15 10000 ±5 87 Outdoor

 

Download

There is currently no content to display
Please add data record on website background.

 Copyright Ⓒ Copyright Shenzhen Yiguang Technology Co., Ltd.  粤ICP备11081863号 Powered by  www.300.cn