75 Watt, Constant Current, LAG75W, Ballast

Product type: Ballast, Constant Current Driver
Application: LED Street Lights, LED Tunnel Lights, LED Grille
Size: 240mm(L)×45mm(W)×32mm(H)
Weight: 650g
Warranty: Five years
Products detail
Product parameters
Series model
Product type:
Ballast, Constant Current Driver
Application:
LED Street Lights, LED Tunnel Lights, LED Grille
Size:
240mm(L)×45mm(W)×32mm(H)
Weight:
650g
Warranty:
Five years

          LAG75W Series, LED Constant Current Drivers

1. Drive Mode: Constant Current

2. Technology: PFC + LLC

3. Output Power: 75W Max.

4. Input Voltage: 120 to 277VAC,47-63HZ

5. Number of Outputs: One

6. Output Voltages: 24 ~ 214Vdc

7. Output Currents: 350mA - 1050mA

8. Safety: EN61347, J61347 ( H20 ), UL8750, CSA C22.2

9. EMC: EN55015, J55015 ( H20 ), FCC 47CFR Part 15 Class B

a. Comply with PSE, CE CCC

b. RoHs compliant;

c. Metal Shell, Asphalt Potting, Tc 90°C Maximum;

d. Compact, Lightweight Design;

e. Water Resistant and Dust Proof Design: IP66, NEMA 13,

    for Dusty, Damp, Wet Locations;

f. Standard electrical box for installation;

g. Active Power Factor Correction technology to reduce

   power consumption;

h. Safety Isolation between Primary and Secondary. 

i. Surge Immunity ( Lightning Protection ):

    Comply with EN61000-4-5, AC line to line 2KV.

Keyword:
Ballast
We could not find any corresponding parameters, please add them to the properties table

1. Operating Temperature: −30 to +60°C, Tc 90°C Maximum;

2. Storage Temperature: −40 to +85°C;

3. Humidity (non-condensing): 5% to 95%RH;

4. Cooling: Convection;

5. Vibration Frequency: 5 ~ 55HZ/2g, 30 minutes;

6. Impact Resistance: 1g/S;

7. MTBF@40°C: 415,000 hours @ Full Load per MIL-217 Notice 2.;

8. LIFE@25°C: 100,000 hours @ Full Load per MIL-217 Notice 2.;

9. Safety: CISPR 22 CLASS A, CISPR 14-1 CLASS A,

                 EN61000-3-2 & EN61000-3-3 Class C,

                 GB19510.14-2009, GB19510.1-2009,

                 GB17743.1-2007, GB17625.1-2003

a. Maximum Input Current: 0.80A (@ 120V, full load);

b. Input Surge Current: <40A (25°C, 230V, cold start);

c. Constant Current Regulation: ±4%, Over Input Line Variation;

d. Load Regulation Accuracy: ±3%;

e. Output Current Ripple: <5%*Io

f. Leakage Current: 400uA typical; Hold up time: half cycle;

g. Protection: Output over-voltage protection;

                      Output over-current protection;

                      Output short circuit, auto-recovery;

                      Lightning & transient protection built in.

Ballast  C. C.

Input

Voltage

Vac

Power Factor

Output

Voltage

Vdc

Constant

Current

mA

Current

Accuracy

%

Typical

Efficiency

%

Location

LAG75W Series

@120V

@230V

LAG75W-214-C0350 120~277 0.99 0.95 71-214 350 ±5 92 Outdoor
LAG75W-142-C0530 120~277 0.99 0.95 47-142 530 ±5 92 Outdoor
LAG75W-108-C0700 120~277 0.99 0.95 36-108 700 ±5 91 Outdoor
LAG75W-72-C1050 120~277 0.99 0.95 24-72 1050 ±5 91 Outdoor

 